High-pressure refrigeration dryers up to 85 m³/min


THP series: Extraordinarily reliable up to 45 bar

Kaeser THP-series refrigeration dryers (*) truly show their mettle when maximum reliability at high working pressures is required – such as in PET container production. High-quality components and excellent manufacturing ensure your units will enjoy premium moisture protection for the long-term – even at high ambient temperatures.

  • Reliably dry compressed air from 8.5 to 85 m³/min
  • For working pressures up to 45 bar
  • For ambient temperatures up to +43 °C

Your advantages

  • Long-term operational reliability:
    With a copper-soldered stainless steel plate-type heat exchanger and generously-dimensioned condenser and heat exchanger, THP refrigeration dryers deliver long-term reliability.
  • Outstanding low differential pressure values:
    All THP dryers shine with optimal differential pressure values thanks to their special flow-optimised pipework made of stainless steel.
  • Condensate drainage without pressure loss:
    The models of the THP series are equipped as standard with a high-pressure version of the ECO-DRAIN 12 condensate drain, which ensures reliable condensate drainage with zero compressed air loss – and tangible energy savings!

* Dryers from this series contain the fluorinated greenhouse gas R-513A.

The perfect partner: the AQUAMAT oil/water separator
Aquamat i.CF 60 oil/water separator

Our tip: Take advantage of cost-effective, legally-compliant treatment of condensate before drainage into the regular wastewater system with AQUAMAT oil/water separators.

 

Product details

Equipment

Design

  • Tower design with removable side panels
  • Powder-coated enclosure panels
  • All materials are CFC-free
  • All cold unit parts are insulated
  • Integrated control cabinet with electronic controller
  • Air/air and air/refrigerant stainless steel plate-type heat exchangers
  • Internal compressed air pipework made of copper
  • Condensate separation system
  • Electronic condensate drain
  • Delivered filled with refrigerant and oil

Refrigerant circuit

  • Refrigerant circuit consisting of reciprocating compressor
  • Fan-condenser assembly
  • Filter dryer
  • Capillary tubes
  • Insulated air/air and air/refrigerant heat exchanger with integrated condensate separator made of stainless steel (copper-soldered)
  • Hot gas bypass controller

Condensate drainage

ECO-DRAIN condensate drain, high pressure version
  • Electronically-controlled ECO-DRAIN 12 condensate drain, high-pressure version
Application example (schematic)
THP high pressure refrigeration dryer – example installation
Technical specifications

The technical specifications can be found in this brochure: